Steelcoat Exposed Surface Coatings

Surface Tolerant Coating Systems for New Construction and Maintenance Projects

Download Brochure Unrivalled Surface Tolerant Coatings (pdf)

Steelcoat Systems for the Protection of Pipebridges

The unique Denso Steelcoat range brings together a diverse but complimentary group of coating systems, all of which are proven to tolerate poorly prepared substrates and still provide long term corrosion prevention performance in hostile atmospheric environments.

Denso Steelcoat 50 System

Injectable petrolatum compound

Download Brochure Steelcoat 50 (pdf)

Download TDS – Denso Void Filler #2

Download TDS – Denso Void Filler #3

A semi-solid specially formulated and blended Petrolatum Compound which is saturated into the pre-stressing strand with a heated bath and die arrangement.

The product exhibits excellent penetrating and wetting characteristics and contains no metallic soaps or volatile components.

Denso Steelcoat 100 System

Universal petrolatum tape system for all structures/ configurations

Download Brochure Steelcoat 100 (pdf)

Download Application Instructions for Steelcoat 100

Download TDS – Denso Hi Tack Primer (pdf)

Download TDS – Denso Hi Tack Tape

Download TDS – Denso D5 Scrim

Download TDS – Denso Elastomeric Membrane BG Coating (pdf)

Download TDS – Denso Single Pack Elastomeric Membrane

Comprises an adhesive petrolatum primer (Denso Hi-Tack Primer) an optional petrolatum paste compatible with damp surfaces (SeaShield Primer P) and a very adhesive petrolatum tape (Denso Hi-Tack Tape).

Back to Top

Denso Steelcoat 200 System

For pipework and fittings at elevated temperatures to 110°C

Download Brochure Steelcoat 200 (pdf)

Download TDS – Denso Hot Line Tape

Download TDS – Densoseal 16A Mastic

Comprises a plastic backed petrolatum tape (Denso Hotline Tape) and a high temperature mastic for sealing fittings and awkward shapes (Densoseal 16A). No primer is required. An adhesive aluminium tape (Denso Sirex Tape) is an optional outerwrap which provides extra mechanical and/or ultra-violet light protection.

Denso Steelcoat 300 System

Self-coloured cold applied petrolatum based tape. Naturally grey coloured cold applied petrolatum based tape for long term corrosion protection. Designed specifically to be resistant to the spread of surface flame.

Download Brochure Steelcoat 300 (pdf)

Download TDS – Densyl-KF-Colourtape

Back to Top

Denso Steelcoat 400 System

A self amalgamating laminate that can be top coated.

Download AI –  Steelcoat 400 (pdf)

Download TDS – Denso Ultraseal Tape

Download TDS – Denso Conforming Tape

Download TDS – Denso Primer D (pdf)

Download TDS – Denso Acrylic Topcoat (pdf)

Download TDS – Denso ST Epoxy Coating

Download TDS – Denso Penetrating Primer

Comprising deep penetrating primer (Denso Penetrating Primer), an easily applied layer of semi-coated acrylic backed tape (Denso Ultraseal Tape) and a choice of final topcoats (Denso Acrylic or Urethane Topcoat). The final topcoat can be reinforced with a selected reinforcing scrim ( Denso D5 or D10 Scrim) for sections of steelwork or pipework which require additional impact resistance. After priming, Denso Profiling Mastic is first utilised to seal and profile back to back angles, voids, flanges or fittings, before application of Denso Ultraseal Tape and selected topcoat.

Denso Steelcoat 700 System

A truly surface tolerant glass flake epoxy mastic coating

Download Brochure Steelcoat 700 (pdf)

Download TDS – Denso ST Epoxy Coating

Comprises a two component glass flake reinforced epoxy mastic coating (Denso S.T. Epoxy). A minimum of two coats is easily applied by brush or airless spray. Denso S.T. Filler is utilised to fill any voids, gaps or bad pits. Denso Stripe Coat ensures high build over edges and bolts. When exposed to ultra-violet light a third coat of Urethane based material (Denso Weathershield) is applied for extra protection (prevents chalking). Light colours of Denso S.T. Epoxy are recommended to ensure the epoxy is fully covered with the final Weathershield topcoat.

Back to Top

Denso Steelcoat 1000 System

Polyester glass flake coating that builds to 1000 micron

Download Brochure Steelcoat 1000 (pdf)

Download TDS – Rigspray Prod Data (pdf)

Comprises a two component reinforced polyester glass flake coating (Denso PGF 1000) that offers outstanding resistance to corrosion and abrasion. The robust coating is applied by either airless spray or brush and can achieve a dry film thickness of 1mm or 1000 microns in one coating operation. Good mechanical resistance of the coatingis achieved within 3 hours at 25°C. For improved service life two coats are applied at 750 microns per coat to increase overall thickness to 1,500 microns average.

Denso Steelcoat 100/400 System

Download AI – Denso Steelcoat 100-400 System (pdf)

Download TDS – Denso MP Primer or Download TDS – Denso Hi Tack Primer (pdf)

Download TDS – Denso Mastic or Download TDS – Denso Superlight Profiling Mastic

Download TDS – Denso Tape or Download TDS – Denso Hi Tack Tape

Download TDS – Ultraseal Reinforcing Tape (RT)

Download TDS – Denso Weatherseal Topcoat (pdf)

For the protection of structural steel, pipes, welded joints, bends, fittings and similar structures from corrosion, above ground. To protect the substrate from corrosion the system completely encases and segregates its surface from the surrounding environment by making intimate contact with the entire exposed substrate.

Back to Top

Denso Tank Base Seal System

Download AI – Denso Tank Base Protection

Download TDS – Denso Primer D or Download TDS – Denso Hi Tack Primer

Download TDS – Denso Superlight Profiling Mastic or Download TDS – Densyl Supersoft Mastic or Download TDS – Denso Mastic

Download TDS – Denso Hi Tack Tape or Download TDS – Densyl Tape or Download TDS – Denso Tape

Download TDS – Ultraseal Reinforcing Tape (RT))

Download TDS – Denso Acrylic Topcoat

For the corrosion protection of tank bases by the prevention of moisture ingress to the underside of the tank base. Tank bases generally sit on asphalt or concrete slabs; at or near the point of contact with the slab moisture can collect which may initiate the corrosion process.